{"id":775,"date":"2026-10-07T22:18:49","date_gmt":"2026-10-07T22:18:49","guid":{"rendered":"https:\/\/staginglab.us\/clarkwf\/?post_type=boiler&#038;p=775"},"modified":"2026-10-07T22:18:49","modified_gmt":"2026-10-07T22:18:49","slug":"hurst-400-series-boiler","status":"publish","type":"boiler","link":"https:\/\/staginglab.us\/clarkwf\/boiler\/hurst-boilers\/scotch-marine\/hurst-400-series-boiler\/","title":{"rendered":"Hurst 400 Series Boiler"},"content":{"rendered":"<h1 class=\"mb-2 mb-md-0\"><span style=\"font-size: 16px;\">THREE-PASS SCOTCH MARINE DESIGN<\/span><\/h1>\n<div class=\"row\">\n<div class=\"col-md-6\">\n<p>LOW PROFILE, WET BACK CONSTRUCTION<\/p>\n<p><i><strong>Available in 8 Models from 100 &#8211; 2000 BHP<\/strong><\/i><strong>\u00a0<\/strong><\/p>\n<p><i><strong>Steam Pressures to 15-300 PSI<\/strong><\/i><strong>\u00a0<\/strong><\/p>\n<p><i><strong>Hot Water Section I and Section IV<\/strong><\/i><strong>\u00a0<\/strong><\/p>\n<p>Wetback design eliminates refractory rear door &amp; baffles between flue gas passes<\/p>\n<ul>\n<li>Natural Gas<\/li>\n<li>Oil<\/li>\n<li>Combination<\/li>\n<li>Steam<\/li>\n<li>Hot Water<\/li>\n<\/ul>\n<h3>Standard Features<\/h3>\n<ul>\n<li>Boiler is of the three-pass, scotch type, built and stamped in accordance with the requirements of the ASME Code, and listed by the National Board of Boilers and Pressure Vessel Inspectors.<\/li>\n<li>Large combustion chamber with low heat release for complete combustion. Smoke box is rear-mounted with slip-on stack connector.<\/li>\n<li>Access to fireside is accomplished with hinged and davited front and rear doors. Flame observation ports are located on front and rear.<\/li>\n<li>Openings for vessel cleanout and inspection of waterside are provided with 3&#8243; x 4&#8243; hand holes, and 12&#8243; x 16&#8243; manway access.<\/li>\n<li>Insulated with 2&#8243; high density mineral wool, lagged with 22 gauge grip jacketing, baked on finish to resist chipping and fading.<\/li>\n<li>Firetubes are rolled and beaded on power boilers, expanded and flared on low pressure boilers.<\/li>\n<li>Supports include lifting lugs securely welded to the top of shell; structural steel support legs on skids support the boiler so that special foundations are not required.<\/li>\n<\/ul>\n<h3>Standard Steam Trim<\/h3>\n<ul>\n<li>Operating &amp; high limit pressure control<\/li>\n<li>Modulating pressure control (when applicable)<\/li>\n<li>Water column with gauge glass, combination low water cut-off &amp; pump control<\/li>\n<li>Probe Aux, L.W.C.O. Steam pressure gauge, syphon &amp; test cock<\/li>\n<li>Water column drain valve<\/li>\n<li>Safety relief valve(s) per ASME Code<\/li>\n<\/ul>\n<h3>Standard Water Trim<\/h3>\n<ul>\n<li>Operating &amp; high limit temperature control<\/li>\n<li>Modulating temperature control (when applicable)<\/li>\n<li>Probe type low water cut-off control<\/li>\n<li>Combination pressure &amp; temperature gauge<\/li>\n<li>Hot water return baffle for shock resistance<\/li>\n<li>Safety relief valve(s) per ASME Code<\/li>\n<\/ul>\n<h3>Boiler Design<\/h3>\n<p>Three-Pass &#8220;Scotch Marine&#8221; Firetube design with stress relieving &#8220;Wetback&#8221; construction. Pressure designs for steam are 15-300 psi. 100-600 hp. 250 psi. max. for 700-1500 hp. and 200 psi. max. for 1800-2000 hp. Hot Water pressures models are from 30-160 psi. High pressure, high temperature Section I hot water boilers available. Factory assembled with trim, tested, ASME code, UL, and CSD-1 standards.<\/p>\n<h3>Steam Model Trim<\/h3>\n<p>Safety relief valve, operating pressure control, high limit pressure control with manual reset, steam pressure gauge with syphon, combination pump control and low water cut-off with gauge glass assembly and drain valve, auxiliary low water cut-off with manual reset.<\/p>\n<h3>Hot Water Model Trim<\/h3>\n<p>Safety relief valve, operating temperature control, high limit temperature control with manual reset, combination pressure &amp; temperature gauge, low water cut-off control with manual reset. BURNER: Matched UL listed &#8220;forced draft&#8221; power burners with factory prepiped, wired and tested fuel configurations for natural gas, propane (LP) gas, No. 2 (diesel) oil, or combination of both gas\/oil.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>THREE-PASS SCOTCH MARINE DESIGN LOW PROFILE, WET BACK CONSTRUCTION Available in 8 Models from 100 &#8211; 2000 BHP\u00a0 Steam Pressures to 15-300 PSI\u00a0 Hot Water Section I and Section IV\u00a0 Wetback design eliminates refractory rear door &amp; baffles between flue gas passes Natural Gas Oil Combination Steam Hot Water Standard Features Boiler is of the [&hellip;]<\/p>\n","protected":false},"featured_media":776,"parent":758,"menu_order":0,"template":"","meta":{"_acf_changed":false},"categories":[],"page-type":[],"class_list":["post-775","boiler","type-boiler","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/boiler\/775","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/boiler"}],"about":[{"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/types\/boiler"}],"up":[{"embeddable":true,"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/boiler\/758"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/media\/776"}],"wp:attachment":[{"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/media?parent=775"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/categories?post=775"},{"taxonomy":"page-type","embeddable":true,"href":"https:\/\/staginglab.us\/clarkwf\/wp-json\/wp\/v2\/page-type?post=775"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}